Responded correctly: was sent a Stateless Reset and went quiet — nothing further arrived in the 3 seconds that followed, which is the draining period §10.3.1 requires.
The client did what the clause requires.
What was measured
- Client
- msquic — .NET HttpClient + msquic, 2.7.0
- Test
- Stateless reset —
q-stateless-reset - Clause
- RFC 9000 §10.3 (MUST)
- Class
- correctness — Rejected something invalid, with the code the RFC names.
- Required behaviour
- Recognise the token in the last 16 bytes of the datagram, enter the draining period, and send no further packets on the connection. The packet cannot be authenticated, so there is nothing to reply with and nothing to report to the peer — continuing to send is the failure §10.3.1 names.
- Measured
- 2026-09-18
Reproduce it
The suite is the judge, so the reproduction is to point the same client at the same test and let the server report what it saw.
SESSION=$(curl -sX POST https://conformance.pqcrypta.com/session | jq -r .id)
# then drive msquic at the test URL and read the verdict:
curl -s https://conformance.pqcrypta.com/report/$SESSION.json | jq '.results["q-stateless-reset"]'
What this suite is · The full grid · All clients · All tests · Findings