The run did not exercise this test: the connection failed during the handshake (detected an error with protocol compliance that was not covered by more specific error codes in STREAMS_BLOCKED_BIDI: illegal frame type in handshake), so the client never reached the anomaly.
The run did not establish what this client does here — either it was never put in the situation, or its answer admits more than one reading. Not a failure, and never counted as one.
What was measured
- Client
- xquic — Alibaba xquic + BoringSSL, 2060a44
- Test
- A second control stream opened by the server —
h-second-control-stream - Clause
- RFC 9114 §6.2.1 (MUST)
- Class
- correctness — Rejected something invalid, with the code the RFC names.
- Required behaviour
- Close the connection with H3_STREAM_CREATION_ERROR.
- Measured
- 2026-09-18
Reproduce it
The suite is the judge, so the reproduction is to point the same client at the same test and let the server report what it saw.
SESSION=$(curl -sX POST https://conformance.pqcrypta.com/session | jq -r .id)
# then drive xquic at the test URL and read the verdict:
curl -s https://conformance.pqcrypta.com/report/$SESSION.json | jq '.results["h-second-control-stream"]'